1. Data overview: This data set is the daily scale meteorological gradient data of Qilian station from October 1, 2011 to December 31, 2011 (installed at the end of September 2011). The observation of vg1000 gradient observation system started on October 1, 2011, recording data every 30 mins, and finally generating daily scale data. Through the long-term monitoring of wind speed and direction, air temperature and humidity, radiation and other conventional meteorological elements, combined with high-precision, high scanning frequency data collector for data storage and processing analysis. 2. Data content: The main observation elements include four layers of air temperature, humidity and two-dimensional ultrasonic wind, rain and snow meter, eight layers of ground temperature, soil moisture, etc. 3. Space time scope: Geographic coordinates: longitude: longitude: 99 ° 52 ′ E; latitude: 38 ° 15 ′ n; altitude: 3232.3m
HAN Chuntan, CHEN Rensheng
This dataset contains data for comprehensive monitoring in the small watershed of Sumu Jaran in the Badain Jaran Desert from 2012 to 2013. The small watershed of Sumu Jaran is composed of two lakes, namely North Lake and South Lake of Sumu Jaran. The latitude and longitude range is: 39° 46' 18.24" to 39° 49' 17.25" north latitude, 102° 23' 40.53 " to 102° 26' 59.27" east longitude. The observation instruments are mainly arranged around the South Lake of Sumu Jaran, including scintillator (BLS450), automatic weather station (net radiation, rainfall, wind speed, wind direction, air humidity, pressure, E601 type evaporation dish), soil monitoring station (soil temperature, water content and tension pF-meter) and one groundwater monitoring hole. The data released this time are the monitoring results from September 2012 to December 2013. Post-monitoring data will be released in version 2.0. For the layout, coordinates, and type of the instrument, see the layout of the small watershed monitoring system.pdf, coordinates of the monitoring point.xls, and location and equipment of the monitoring point.tif.
HU Xiaonong, WANG Xusheng
This dataset contains the flux measurements from site No.9 eddy covariance system (EC) in the flux observation matrix from 4 June to 17 September, 2012. The site (100.38546° E, 38.87239° N) was located in a cropland (maize surface) in Yingke irrigation district, which is near Zhangye, Gansu Province. The elevation is 1543.34 m. The EC was installed at a height of 3.9 m; the sampling rate was 10 Hz. The sonic anemometer faced north, and the separation distance between the sonic anemometer and the CO2/H2O gas analyzer (Gill&Li7500A) was 0.2 m. Raw data acquired at 10 Hz were processed using the Eddypro post-processing software (Li-Cor Company, http://www.licor.com/env/products/ eddy_covariance/software.html), including spike detection, lag correction of H2O/CO2 relative to the vertical wind component, sonic virtual temperature correction, angle of attack correction, coordinate rotation (2-D rotation), corrections for density fluctuation (Webb-Pearman-Leuning correction), and frequency response correction. The EC data were subsequently averaged over 30 min periods. Moreover, the observation data quality was divided into three classes according to the quality assessment method of stationarity (Δst) and the integral turbulent characteristics test (ITC), which was proposed by Foken and Wichura [1996]: class 1 (level 0: Δst<30 and ITC<30), class 2 (level 1: Δst<100 and ITC<100), and class 3 (level 2: Δst>100 and ITC>100), representing high-, medium-, and low-quality data, respectively. In addition to the above processing steps, the half-hourly flux data were screened in a four-step procedure: (1) data from periods of sensor malfunction were rejected; (2) data before or after 1 h of precipitation were rejected; (3) incomplete 30 min data were rejected when the missing data constituted more than 3% of the 30 min raw record; and (4) data were rejected at night when the friction velocity (u*) was less than 0.1 m/s. There were 48 records per day; the missing data were replaced with -6999. Moreover, suspicious data were marked in red. The released data contained the following variables: data/time, wind direction (Wdir, °), wind speed (Wnd, m/s), the standard deviation of the lateral wind (Std_Uy, m/s), virtual temperature (Tv, ℃), H2O mass density (H2O, g/m^3), CO2 mass density (CO2, mg/m^3), friction velocity (ustar, m/s), stability (z/L), sensible heat flux (Hs, W/m^2), latent heat flux (LE, W/m^2), carbon dioxide flux (Fc, mg/ (m^2s)), quality assessment of the sensible heat flux (QA_Hs), quality assessment of the latent heat flux (QA_LE), and quality assessment of the carbon flux (QA_Fc). In this dataset, the time of 0:30 corresponds to the average data for the period between 0:00 and 0:30; the data were stored in *.xlsx format. For more information, please refer to Liu et al. (2016) (for multi-scale observation experiment or sites information), Xu et al. (2013) (for data processing) in the Citation section.
LIU Shaomin, LI Xin, XU Ziwei
The dataset of meteorological station observations (2008-2009) was obtained at the Yeniugou cold region hydrological station (E99°33'/N38°28', 3320m), Qilian county, Qinghai province. Observation items were multilayer (2m and 10m) of the air temperature and air humidity, the wind speed and direction, the air pressure, precipitation, the global radiation, the net radiation, the multilayer soil temperature (20cm, 40cm, 60cm, 80cm, 120cm and 160cm), soil moisture (20cm, 40cm, 60cm, 80cm, 120cm and 160cm), and soil heat flux. For more details, please refer to the attached Data Directions.
CHEN Rensheng, YANG Yong, Wang Weizhen, LI Xin
1. Data overview: Eddy covariance system is a micrometeorological measurement method.It USES the principle of vorticity correlation to measure the material exchange and energy exchange of the atmosphere cushion surface with a fast response sensor.The core of open circuit eddy covariance system is composed of CR1000 data collector, CSAT3 3d ultrasonic wind speed and direction sensor, and li-7500 open circuit CO2/H2O gas analyzer (EC150).The eddy covariance system is a newly purchased instrument of this project, which takes a long time to order. It was installed in early October 2011, and the data is relatively short.This data set is the vorticity covariance data of qilian station from October 1, 2011 to December 31, 2011 at 30min. 2. Data content: The observation items are: horizontal wind speed Ux (m/s), horizontal wind speed Uy (m/s), vertical wind speed Uz (m/s), ultrasonic temperature Ts (Celsius), co2 concentration (mg/m^3), water vapor concentration (g/m^3), pressure press (KPa).The data sampling rate is 10Hz per second. 3. Space and time range: Geographical coordinates: longitude: 99° 52’e;Latitude: 38°15 'N;Height: 3232.3 m
CHEN Rensheng, HAN Chuntan
This dataset includes data recorded by the Heihe integrated observatory network obtained from an observation system of Meteorological elements gradient of Daman Superstation from January 1 to December 31, 2018. The site (100.372° E, 38.856° N) was located on a cropland (maize surface) in the Daman irrigation, which is near Zhangye city, Gansu Province. The elevation is 1556 m. The installation heights and orientations of different sensors and measured quantities were as follows: air temperature and humidity profile (AV-14TH;3, 5, 10, 15, 20, 30, and 40 m, towards north), wind speed and direction profile (windsonic; 3, 5, 10, 15, 20, 30, and 40 m, towards north), air pressure (CS100; 2 m), rain gauge (TE525M; 2.5 m, 8 m in west of tower), four-component radiometer (PIR&PSP; 12 m, towards south), two infrared temperature sensors (IRTC3; 12 m, towards south, vertically downward), photosynthetically active radiation (LI190SB; 12 m, towards south, vertically upward; another four photosynthetically active radiation, PQS-1; two above the plants (12 m) and two below the plants (0.3 m), towards south, each with one vertically downward and one vertically upward), soil heat flux (HFP01SC; 3 duplicates with G1 below the vegetation; G2 and G3 between plants, -0.06 m), a TCAV averaging soil thermocouple probe (TCAV; -0.02, -0.04 m), soil temperature profile (AV-10T; 0, -0.02, -0.04, -0.1, -0.2, -0.4, -0.8, -1.2, and -1.6 m), soil moisture profile (CS616; -0.02, -0.04, -0.1, -0.2, -0.4, -0.8, -1.2, and -1.6 m). The observations included the following: air temperature and humidity (Ta_3 m, Ta_5 m, Ta_10 m, Ta_15 m, Ta_20 m, Ta_30 m, and Ta_40 m; RH_3 m, RH_5 m, RH_10 m, RH_15 m, RH_20 m, RH_30 m, and RH_40 m) (℃ and %, respectively), wind speed (Ws_3 m, Ws_5 m, Ws_10 m, Ws_15 m, Ws_20 m, Ws_30 m, and Ws_40 m) (m/s), wind direction (WD_3 m, WD_5 m, WD_10 m, WD_15 m, WD_20 m, WD_30m, and WD_40 m) (°), air pressure (press) (hpa), precipitation (rain) (mm), four-component radiation (DR, incoming shortwave radiation; UR, outgoing shortwave radiation; DLR_Cor, incoming longwave radiation; ULR_Cor, outgoing longwave radiation; Rn, net radiation) (W/m^2), infrared temperature (IRT_1 and IRT_2) (℃), photosynthetically active radiation (PAR) (μmol/ (s m-2)), average soil temperature (TCAV, ℃), soil heat flux (Gs_1, below the vegetation; Gs_2, and Gs_3, between plants) (W/m^2), soil temperature (Ts_0 cm, Ts_2 cm, Ts_4 cm, Ts_10 cm, Ts_20 cm, Ts_40 cm, Ts_80 cm, Ts_120 cm, and Ts_160 cm) (℃), soil moisture (Ms_2 cm, Ms_4 cm, Ms_10 cm, Ms_20 cm, Ms_40 cm, Ms_80 cm, Ms_120 cm, and Ms_160 cm) (%, volumetric water content), above the plants photosynthetically active radiation of upward and downward (PAR_U_up and PAR_U_down) (μmol/ (s m-2)), and below the plants photosynthetically active radiation of upward and downward (PAR_D_up and PAR_D_down) (μmol/ (s m-2)). The data processing and quality control steps were as follows: (1) The AWS data were averaged over intervals of 10 min for a total of 144 records per day.The meterological data during September 17 and November 7 and TCAV data after November 7 were wrong because the malfunction of datalogger. The missing data were denoted by -6999. (2) Data in duplicate records were rejected. (3) Unphysical data were rejected. (4) The data marked in red are problematic data. (5) The format of the date and time was unified, and the date and time were collected in the same column, for example, date and time: 2018-6-10 10:30. Moreover, suspicious data were marked in red. For more information, please refer to Liu et al. (2018) (for sites information), Liu et al. (2011) for data processing) in the Citation section.
LI Xin, CHE Tao, XU Ziwei, REN Zhiguo, TAN Junlei
1. Data overview: This data set is eddy covariance Flux data of qilian station from January 1, 2012 to December 31, 2012. 2. Data content: The observation items are: horizontal wind speed Ux (m/s), horizontal wind speed Uy (m/s), vertical wind speed Uz (m/s), ultrasonic temperature Ts (Celsius), co2 concentration co2 (mg/m^3), water vapor concentration h2o (g/m^3), pressure press (KPa), etc.The data is 30min Flux data. 3. Space and time range: Geographical coordinates: longitude: 99° 52’e;Latitude: 38°15 'N;Height: 3232.3 m
CHEN Rensheng, HAN Chuntan
1. Data overview: This data set is eddy covariance Flux data of qilian station from January 1, 2013 to December 31, 2013. 2. Data content: The observation items are: horizontal wind speed Ux (m/s), horizontal wind speed Uy (m/s), vertical wind speed Uz (m/s), ultrasonic temperature Ts (Celsius), co2 concentration co2 (mg/m^3), water vapor concentration h2o (g/m^3), pressure press (KPa), etc.The data is 30min Flux data. 3. Space and time range: Geographical coordinates: longitude: 99° 52’e;Latitude: 38°15 'N;Height: 3232.3 m
CHEN Rensheng, HAN Chuntan
The meteorological field is located at 3200m above sea level in Pailugou watershed of Qilian Mountain, which belongs to the high mountain forest line zone, the ecotone of Picea crassifolia forest and alpine shrub. This data set includes precipitation, air temperature, radiation, wind speed, etc., with units are mm, ℃, W/m^2 and m/s respectively. The date of data recording is from June 2012 to October 2013, in which the temperature data is partially missing due to the instrument.
HE Zhibin
Contact Support
Northwest Institute of Eco-Environment and Resources, CAS 0931-4967287 poles@itpcas.ac.cnLinks
National Tibetan Plateau Data CenterFollow Us
A Big Earth Data Platform for Three Poles © 2018-2020 No.05000491 | All Rights Reserved | No.11010502040845
Tech Support: westdc.cn